ISO9001
IEC61010-1
BS/EN61326
EN60950
CE
|
The TX6000 is a hand held
Time Domain Reflectometer with 11 range scales covering the range
0-6000 meters, with a 7 meter first range scale and a 0.5 meter
dead zone. Near and far end faults are clearly displayed on its
128x64 pixel back light Liquid Crystal Display.
USB 2.0 interface with Windows compatible
software 'TraceXtra' gives the user an option to download
and analyse saved traces to a windows PC. Also the interface allows
the user to upload saved traces from PC hard disk to the unit. New
firmware upload feature gives the facility to update the unit (TDR)
with recent additions.
Designed for identifying and locating
faults on all metallic cables with two or more insulated conductors.
The TX6000 has impedance matched circuits for 25, 50, 75 and 100
ohms and with velocity of propergation settings from 1-99% (or the
equivalent in feet or meters/micro second) will cover the range
of power, data, communication and CCTV cables.
Housed in a rugged IP54 rated ABS
enclosure and weighing only 350 grams (12 ounces), the TX6000 is
suitable for outside use.
Features
- USB 2.0 Interface with Windows®
compatible software TraceXtra to download/analyse traces
- Rugged Palm-Top design
- Weighs less than 350g (12oz)
- 11 Measurement Ranges up to 6000m
(6km)
- 25, 50, 75 & 100ohm Selectable
Cable Impedance
- Memory capacity up to 50 saved
traces
- Built in Tone Generator for Pair
Tracing and Identification
- Suitable for testing all Communication
and Power Cables
- Environmental Protection IP54
- CE Approved
- Soft bag & Test Leads
Specifications
| Ranges
@ Vp-70% |
Meters:
7, 15, 30, 60, 120, 250, 500,
1km, 2km, 3km, 6km
Feet: 23, 49, 98, 197, 394, 820, 1640,
3280, 6560, 9850, 19000
|
Power
Supply |
6v
(4 x AA cells) |
| Range
Selection |
Manual
range control
|
Power
Down Selectable |
1,
2, 3, 5 minutes or disabled |
| Resolution |
Approximately
1% of range |
Backlit
Display
|
128
x 64
pixels |
| Accuracy |
1%
of selected range* |
Voltage
Detection |
250
volts AC |
| Sensitivity |
min
3 pixel return at 4km
on 0,6mm, PE, TP
|
Storage
Temperature |
-20
to 70 deg. C |
| Velocity
Factor |
Adjustable
from 1% to 99% |
Operating
Temperature |
10
to 50 deg. C |
| Output
Pulse |
5v
p-p into open circuit |
Dimensions |
165
x 90 x 37mm |
| Output
Impedance |
Selectable
25, 50, 75 and 100 ohms |
Weight |
350gms
(12oz) |
Output
Pulse
Width |
3ns
min to 3ms, automatic range |
Water/Dust
Proof |
IP54 |
| Scan
Rate |
2
scans / second or scan held
(not on 3km/6km range) |
Safety |
IEC61010-1
EN 60950 |
| Tone
Generator |
810
- 1110 Hz |
EMC |
BS/EN61326-1 |
| Battery
Life |
60
hours continuous scanning |
|
|
*Measurement accuracy of +/-1%
assumes the instrument setting for velocity
of propagation (Vp) of the cable under test to be accurately set,
homogeneity
of the Vp along the cable length, and accurate cursor positioning.
|
|